Minggu, 12 Mei 2013

SWITCHING REGULATOR TIDAK KERJA (switching berfungsi ganda utk stand by dan main regulator) sprt str 6707

      Tidak mau stand by......
  1. Periksa ic regulator pd c-e transistor powernya, apakah short atau tdk..........ic regulator
  2. Periksa resistor (0.22-0.33) dari ic ke ground.............resistor
  3. Periksa tegangan dc input 300v...........dioda bridge,fguse, resistor soft star,main sw
  4. Periksa tegangan vcc(6-9v) utk ic bagian osc.........resistor(utk teg start)
  5. Periksa trnsistor regulator yg berfungsi utk menyuply ic bagian osc dr tranfo switching.........transistor,zener dioda,dioda,resistor
  6. Ganti tranfo switching.........tranfo switching.


    ADA BUNYI NGERIK PD TRANFO SWITCHING


  1. Periksa tegangan dc300v,mungkin over karena rangkaian doubler aktip pd tegangan 220v...........rangkaian doubler
  2. Periksa jalur pulsa horisontal dr hvt ke bagian regulator...........jalur putus.